The New DPI620 Genii IS Multifunction Druck Calibrator- Safety in your Hands

GE Measurement and Control Nov 03, 2016 No Comments
The New Multifunction Druck Calibrator  
The new Druck DPI620 Genii IS multifunction druck calibrator combines best-in-class performance with ATEX and IECEx approvals for use in hazardous areas. Robust and weather-proof, the Genii IS puts you in control of all your pressure, electrical, temperature and frequency testing, with flexibility and accuracy giving you elite performance wherever you need it. Safety in your hands. Strong, light, intelligent And great under pressure. Packed with performance enhancing features, the Genii IS operates as a 3 in 1 calibrator, test meter and HART/Foundation Fieldbus communicator in hazardous zones where explosive gas and air mixtures can occur. Incorporating tool-free battery management with interchangeable battery packs, easy-to-use touch-swipe screen and daylight readable display as well as being the smallest and lightest calibrator of its type. When it comes to having all your calibration needs covered, stay safe, and stay ahead with the DPI620 Genii IS.  

Calibration management software that empowers you

Calibration, GE Measurement and Control May 10, 2016 No Comments
 calibration management software

Calibration Management Software

Brochure

GE’s new Intecal v10 calibration management software provides an easy to use solution that integrates calibration scheduling, workflow, data collection, analysis and reporting into one automated system.
A fully automated paperless Calibration solution
  • Saves time by cutting out laborious paper work- 100% paper free calibration
  • Significantly improves productivity by integrating with leading calibrators
  • Makes calibration processes easier, simpler and more efficient
Always compliant and performant
  • Improves safety and reliability by reducing documentation time and errors
  • Supports GE’s Druck range of calibrators and others using FCINTF protocol
Imagine. Paper-free calibration. Data you need on hand. Error free & compliant.

GE Druck DPI611 Carry case available now!

GE Measurement and Control May 29, 2015 No Comments
Druck dpi611 carry case

Druck DPI611 Carry case

The Druck DPI611 carry case is made specifically to protect the Druck dpi611 calibrator.
  • Made from durable leather
  • DPI 611 can be used without removal
  • Pocket for test leads
  • Permits use of the hand strap
  • Shoulder strap provided
  • DPI 611 secured  - won’t fall out
  • Reinforced to protect the display
  • Battery and USB access
  • Anti-slip feet
OIH is the agent for Druck products in South Africa and is backed by a team hat has the technical knowledge and expertise to provide quality service on all of these products. For more information please contact us. We will be happy to assist you.

Calibration Management Software Update-GE Druck 4Sight

GE Measurement and Control May 12, 2015 No Comments
product notice calibration management software

4sight calibration management software

4Sight includes the latest driver to link the DPI 611, DPI 620 Series (including Genii and IS versions) and the PACE series to this scalable on premise or cloud based calibration management solution. The driver provides download/upload communications for the field calibrators and real time connection for workshop calibrators and multiple instrument calibration systems, for example, PACE controllers used in conjunction with the DPI 620 Genii.

Additions for Release 6.2.5.0

Data Import for Loops Loops and their associated Components can now also be imported using the Data Import screen in 4Sight. The Import Template has been updated to include an additional sheet

Issue In Bulk Notification When a list of Routines are selected from the Issue in Bulk page and the user clicks the Issue button, a popup will appear notifying the user that there will be selected number of Work Orders issued for the selected number of Routines. The user will be given the option to select Yes or No. When selecting Yes the system will proceed with issuing the selected Routines. When selecting No the system will not proceed and no Routines will be issued.

Routine Graph Information When the Work History Graph is viewed from the Routine Graph page, the Instrument Tag name and the Routine name are now displayed at the top of the graph.

Audit Trail New Data Updates Currently, when creating a new table record, the table fields whose value on creation does not differ from the default value for that field does not get recorded in the Audit Trail Details Table. The table fields whose value on creation differ from the default for that field do get recorded in the Audit Trail Details Table.

The Audit Trail Details table have been updated so that when a new record is created then the full list of fields relating to the new record will be recorded in the Audit Trail Details Table, regardless of whether their value has been modified from the default or not.

For example, when creating a Routine, the Input From value is defaulted to 0.0 on Routine creation. If the user assigns a value of 100 to the Input To option, without modifying the 0 value of the Input From option, when saving the routine with the Input Range 0 to 100, only the Input To value is logged in the Audit Trail Details. However, with these new Audit Trail updates the value of Input From as 0 will also be recorded, even if it is the same as the default value.

There have been no changes in the Audit Trail User Interface and there have been no changes to the Audit Trail main functionality. Also, there have been no changes to the Audit Trail Details table when editing a record.

Master Calibration List Excel Report The “Export to Excel” table button in the Instrument and Loop list pages have been updated to export the “Master Calibration List” to Excel. This report contains the following information for each Instrument or Loop:

Instrument Tag Description SOP Routine Name Last Date
Next Date Critical Interval IntervalType Ref Instrument
Status History Status Complete At Entry Out Of Cycle Deviation Allowable Overrun
Item Type Plant Area Class Company
Department Location Supplier Manufacturer Instrument Type
Type And Model Serial No Comments Purchase Date Purchase Cost
Purchase Order No Order Code Service Status In Service Date PID Code
Service Job No Computer Test Inst Identity Traceability
Certificate No Equipment No Ambient Temp Humidity Barometric Pressure
User Defined Field 1 User Defined Field 2 User Defined Field 3 User Defined Field 4 User Defined Field 5
User Defined Field 6 User Defined Field 7 User Defined Field 8 User Defined Field 9 User Defined Field 10
User Defined Field 11 User Defined Field 12 User Defined Field 13 User Defined Field 14 User Defined Field 15
User Defined Field 16 User Defined Field 17 User Defined Field 18 User Defined Field 19 User Defined Field 20
Input From Input To Output From Output To Cal Points
Output Points Lower Instrument Tolerance (-Adjust Level) Upper Instrument Tolerance (+Adjust Level) Input Unit Output Unit
Range Resolution Lower Process Tolerance Upper Process Tolerance Tolerance Type Points

KPI Filtering

The KPIs reports have been updated to provide the ability to filter the results by Class, Area and Plant. The KPI reports that have been updated are the following:

  • Item Service Status
  • Work Order Planned versus Unplanned
  • Work Order Status
  • Work Order Efficiency
  • Deviations
  • Task Results
  • Work Orders Due
  • References Used
  • Work Order Stock versus Time Cost
  • Work Order Actual Time Exceeds Estimated Time

Total Number of Records in Reports

The Reports in the Reports section of 4Sight have been updated to include the Total Number of records present in the generated reports.

The Reports that have been updated to display this additional information are the following:

  • Listings
  • References Used
  • Deviation Listings
  • Failed Tasks
  • Work Orders Done
  • Down Time
  • Due Date
  • Estimated vs Actual
  • History By Due Date
  • Labour and Stock Costings
  • Labour Costings
  • Work Order Labour Costings

Note: Any Reports not included in the above list either already display a total of the records in the report or is not applicable for displaying total number of records.

Additions for Previous Release 6.2.4.1

Company Name Editing

When an Instrument is in Edit Mode, a user is now able to edit the Company provided that the Company does not have any Routines in cycle.  Historical Work Order data is not changed when the Company or Department is changed for an Instrument.

References Filtering

When the “Filter by Company Department” configuration option is ON and the user has the “Use Filtering” option selected, then when issuing/entering a Work Order, the References list will display only those Reference Instruments available to the Company/Departments that the user is assigned to. Otherwise, all the reference instruments appear in the available list.

When the references are filtered then a “Show All” option is made available which allows a user to override the filtering and display all references for all companies and departments.

When the “Show All” option is checked or unchecked, the “Selected” list will remain the same and the “Available” list will be updated with the relevant References.

If a Selected Reference is de-selected it will be moved to the “Available” List regardless of the Show All option at the time of the de-selection. This will allow the user to re-select the Reference in the case where the reference was de-selected in error.

ERP Integration

The Work Order Configuration has been updated to include ERP System, ERP Authentication credentials and default Maintenance Cert Type for the ERP System. This allows for integrations with ERP systems.

Failed By User Deviation Message

When a Critical Routine is failed by a user using the “Failed By User” options, a deviation is created. Previously the deviation message would read “Calibration failed by user.” This message has been updated to instead read “Work Order failed by user” in order to make it more generic and allowing it to be applicable to non-calibration Work Orders.

Resolution “0”

4Sight has been updated to allow for a resolution of “0” for the Routine Type, Routine values tab and the Work Order Edit values tab. The accepted Resolution Range is not 0 to 5 instead of 1 to 5.

Crystal Reports Module

4Sight has been updated to allow for the inclusion of Crystal Reports based Certificates and Reports.

Cancelled/Rejected Status

When a Work Order is Cancelled or Rejected, a status message now appears on the applicable Work Order Certificate in Bold Red. For Cancelled Work Orders this message will read ‘Cancelled’ and for Rejected Work Orders this message will read ‘Rejected’.

The affected certificates are as follows:

  • Instrument Calibration Sheets
  • Loop Calibration Sheets
  • Instrument General Work Sheet
  • Loop General Work Sheets
  • Work Requests
  • PM Work Sheet

GE Smarter Calibration & Maintenance Webinar now Available on Demand

GE Measurement and Control Jul 23, 2014 No Comments
 
Now Available On-demand! GE Smarter Calibration & Maintenance Webinar  
webinarThe Smarter Calibration & Maintenance Webinar is now available on-demand for you to view anytime!   The webinar explores the gains achieved by implementing a smart calibration regime, such asimproved productivity, increased capacity, reduced downtime, cost savings and compliance. Whilst the presentation highlights the capabilities of our products (DPI620 Genii and 4Sight), the main objective of the presentation is to educate potential customers and address the day-to-day challenges of calibration, including:  
  • Background to the evolution of portable calibration and the development of paperless calibration.
  • Show the gains achieved from combined calibration and communication in today’s world of HART and Fieldbus and the incorporation of calibration into maintenance regimes.
  • Introduce the latest in portable calibration/communication technology (DPI 620 Genii)
  • Conclude with an insight into the world of web-based calibration management systems (4Sight) and how they interface with CMMS and high end ERP software.
  Click-here to view the webinar now!  

The New Druck DPI 611 Pressure Calibrator

Calibration, GE Measurement and Control Jun 06, 2014 No Comments
dpi 611 pic  
When the pressure’s on – there’s a smarter way to work For 30 years the DPI 600 series has been the benchmark for accuracy and pressure generation, and today the DPI 610 is the industry standard simply referred to as the “Druck”. The new DPI 611 builds on this legacy to provide a highly dependable, quick and simple solution to streamline your pressure maintenance and calibration routines.
  • 50% smaller and 33% lighter than the DPI 610
  • Generates 0 to 20 bar in less than 30 secs (test device connected by 1 m hose)
  • Pressure measurement twice as accurate (accuracy now defined as uncertainty including one year stability and temperature errors)
  • Three times better electrical accuracy
  • Simplified touch screen interface with application DASHBOARD, quick TASK selection and FAVOURITES storage
  • As easy as 1, 2, 3 - three touch set-up for any application
  • Calculates PASS/FAIL errors, documents results and interfaces with Calibration Software
footer

DPI 620 Genii

Calibration Apr 29, 2014 No Comments